Moulded CR (Neoprene) oil resistant and non ageing rubber upper chamber with integral aluminium (SLM 1-12) and zinc plated steel (SLM24+) support plate with tapped attachment hole, side wall reinforcement and integral base ring bolted and sealed onto a aluminium (SLM 1-12) and zinc plated steel ( SLM24+) baseplate.
Baseplate can be bolted down to support surface if required. Standard version with Schraeder Inlet Valve.
Other valves on request.
Ratio of vertical to horizontal stiffness ca 1:1
Shock absorption amplitude up to 15mm
Natural Frequency range (depending on load) 2.8-5 Hz (see table).
Deflated (no air pressure): ca 8Hz See Load Spreader Plates LSP.
CMMs, Surface Plates, Presses, Test Beds, Turret Punch Presses, HVAC Scientific and Test Equipment.
+/- 5 (6)mm (see table)
Delivered with Grade 8.8 Zinc plated attachment screw (Other screw lengths available)
Self controlled levelling versions available with either mechanical-pneumatic or electro-pneumatic controllers.
Full proposals on application
Load spreader plates LSP, It is important that the foot of the supported equipment covers the SLM fully.
Load spreader plates LSP can inserted between the top of the SLM and the underside of the machine foot if necessary.
| SLM Isolators | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Model | Load capacity | Maximum Pressure bar | ||||||||||||||
| Empty Height | Attachement screw Thread | Max. Foot | Levelling Adjustment | Base | Fixing Hole Ctrs | Fixing Hole Dia | Base thickness | Unit Mass | ||||||||
| Min. kN |
Max kN |
D mm |
Ho | D1 mm |
M mm |
L mm |
thickness mm |
Le mm |
X mm |
L mm |
C mm |
d mm |
t mm |
|||
| SLM 1 A | 0.1 | 0.65 | 5 | 73 | 65 | 28 | M10x1.5 | 80 | 50 | +/- 5 | 12 | 75 | 60 | 7 | 3 | 0.3 |
| SLM 3 A | 0.35 | 1.8 | 5 | 105 | 65 | 52 | M12x1.75 | 100 | 65 | +/-5 | 12 | 105 | 89 | 7 | 3 | 0.7 |
| SLM 6 A | 0.7 | 2.8 | 6 | 127 | 90 | 60 | M12x1.75 | 100 | 65 | +/-6 | 15 | 130 | 108 | 7 | 3 | 1 |
| SLM 12 B | 1.35 | 6 | 6 | 172 | 90 | 96 | M12x1.75 | 100 | 65 | +/-6 | 15 | 175 | 153 | 7 | 3 | 1.8 |
| SLM 24 A | 2.7 | 13 | 6 | 245 | 90 | 138 | M16x2 | 120 | 75 | +/-6 | 15 | 255 | 215 | 14 | 5 | 5.4 |
| SLM 48 A | 5.5 | 26 | 6 | 338 | 90 | 205 | M16x2 | 120 | 75 | +/-6 | 15 | 343 | 305 | 14 | 5 | 10.7 |
| SLM 96 A | 11 | 55 | 6 | 468 | 90 | 300 | M24x1.5 | 130 | 75 | +/-6 | 15 | 470 | 406 | 20 | 6 | 29.1 |
| SLM 192 A | 22 | 100 | 6 | 610 | 90 | 430 | M24x1.5 | 130 | 75 | +/-6 | 15 | 610 | 508 | 20 | 6 | 38.6 |
Order example SLM 24 A M16x120
| Natural Frequencies v load v air pressure | |||||||
|---|---|---|---|---|---|---|---|
| Air Pressure | bar | 1 | 2 | 3 | 4 | 5 | 6 |
| Vertical Natural Frequency | Hz | 5.6 | 4.2 | 3.6 | 3.2 | 2.9 | 2.7 |
| Horizontal Natural Frequency | Hz | 5.6 | 4.2 | 3.6 | 3.2 | 2.9 | 2.7 |
| Model | Maximum Static+Dynamic Load per unit kg (daN) | ||||||
| SLM 1 A | 5 | 25 | 38 | 52 | 65 | ||
| SLM 3 A | 33 | 78 | 123 | 155 | 180 | ||
| SLM 6 A | 55 | 112 | 178 | 224 | 260 | 280 | |
| SLM 12 B | 110 | 190 | 300 | 390 | 450 | 600 | |
| SLM 24 A | 220 | 500 | 800 | 1000 | 1160 | 1300 | |
| SLM 48 A | 360 | 1000 | 1600 | 2000 | 2300 | 2600 | |
| SLM 96 A | 1050 | 2100 | 3400 | 4200 | 5000 | 5500 | |
| SLM 192 A | 1700 | 3900 | 6100 | 7700 | 9000 | 10000 | |
| SLM Load Spreading Plates LSP | |||||
|---|---|---|---|---|---|
| LSP | For | Do mm |
Di mm |
t mm |
Mass kg |
| 100 | SLM 1 | 100 | 11 | 6 | 0.5 |
| 120 | SLM 3/6 | 130 | 13 | 8 | 0.8 |
| 175 | 12 | 175 | 13 | 10 | 2 |
| 240 | 24 | 240 | 17 | 10 | 3.6 |
| 380 | 48 | 380 | 26 | 12 | 10.3 |
| 550 | 96/192 | 550 | 26 | 15 | 28 |
Silver Painted steel plate
Order example LSP 100
Do not exceed:
Maximum Pressure:
SLM 1 and 3: 5 bar
SLM 12-192: 6 bar
Maximum Working Height:
SLM 1 and 3: 70mm
SLM 12-192: 96mm
Do not pressurise unit without load or restricting vertical movement
1. Pre-installation: Ensure floor is flat and free of debris. Ensure unit’s bearing plate is totally covered by machine foot (use spreader plate where necessary)
2. Installing: Lift the machine to the required height using jacks or levelling units. Slide units into position ensuring valves are accessible. Insert packing plates as necessary (ensure bearing plate will not tilt when units are pressurised.)
3. Fixing: Fix the stud in position using low torque only. Assemble clamping nut and washer
4. Levelling: Pressurise units to a height at or near the maximum Ho+5 (6), ensuring that the maximum pressure allowed is not exceeded. Deflate units in small steps to level machine as necessary, ensuring minimum height
Ho-5 (6) is not exceeded. If necessary repressurisation may be required during leveling. In which case do not exceed maximum pressure 5 (6) bar and/or height Ho+5 (6). Continue leveling until height tolerance and desired levels are reached..
5. Anchoring: Units can be anchored to the floor using the base plate holes.
6. Service: It is recommended that the unit pressure be measured at least once a year Machine should be out of action before pressure checks are taken
7. Dismounting: Units must be fully deflated before removal from under machine. Provision should be made for machine support during deflating operation.
8. Depressurisation: In the event of complete loss of air pressure and machine foot (with or without Load Spreader Plate LSP) covers the SLM completely, the machine base will come in contact with the side walls which are designed to support load well in excess of inflated loading. However in deflated condition the vibration isolation properties will be reduced.
If foot of machine/equipment does not cover the SLM fully, use relevant LSP spreader plate between SLM and machine foot.